Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Electrokinetic-assisted gating in a microfluidic integrated Si nanoribbon ion sensor for enhanced sensitivity
KTH Royal Institute of Technology, Sweden.
KTH Royal Institute of Technology, Sweden ; Uppsala University, Sweden.
RISE - Research Institutes of Sweden, ICT, Acreo.
KTH Royal Institute of Technology, Sweden.
2018 (engelsk)Inngår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 262, s. 974-981Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Using the electrokinetic principle, we demonstrate a novel approach to modulate the response of an ion sensitive silicon-nanoribbon field-effect-transistor, effectively manipulating the device sensitivity to a change in surface potential. By using the streaming potential effect we show that the changes in the surface potential induced by e.g. a pH change can be accurately manipulated in a microfluidic-integrated chip leading to an enhanced response. By varying the flow velocity and the biasing condition along the microfluidic channel, we further demonstrate that the pH response from such a device can also be suppressed or even reversed as a function of the flow velocity and the biasing configuration. Experiments performed with different pH buffer shows that the sensor response can be enhanced/suppressed by several times in magnitude simply by using the streaming potential effects. A mathematical description is also presented for qualitative assessment of the electrokinetic influence on the gate terminal under different biasing condition. The approach presented here shows the prospect to exploit the electrokinetic modulation for developing highly sensitive nanoscale biosensors.

sted, utgiver, år, opplag, sider
2018. Vol. 262, s. 974-981
Emneord [en]
Electrokinetic effect, Ion sensitive field-effect transistor, Microfluidics, pH sensing, Silicon nanoribbon, Streaming potential, Electrodynamics, Field effect transistors, Flow velocity, Ion sensitive field effect transistors, Ions, Nanoribbons, pH effects, pH sensors, Surface potential, Enhanced sensitivity, Mathematical descriptions, Nanoscale biosensors, Qualitative assessments
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-33420DOI: 10.1016/j.snb.2018.02.017Scopus ID: 2-s2.0-85042270625OAI: oai:DiVA.org:ri-33420DiVA, id: diva2:1188806
Merknad

Funding details: 2016-05051, VR, Vetenskapsrådet; Funding details: Familjen Erling-Perssons Stiftelse; Funding details: 2011.0113, Knut och Alice Wallenbergs Stiftelse; Funding text: The authors acknowledge financial support by the Knut and Alice Wallenberg foundation (contract no ( 2011.0113 )), Erling-Persson Family foundation and the Swedish Research Council ( 2016-05051 ).

Tilgjengelig fra: 2018-03-08 Laget: 2018-03-08 Sist oppdatert: 2018-03-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus
Av organisasjonen
I samme tidsskrift
Sensors and actuators. B, Chemical

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 67 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.46.0