Techno-economic evaluation of biogas upgrading using ionic liquids in comparison with industrially used technology in Scandinavian anaerobic digestion plants
Luleå University of Technology, Sweden ; Shandong University of Technology, China.
RISE - Research Institutes of Sweden, Samhällsbyggnad, Energi och cirkulär ekonomi.ORCID-id: 0000-0002-5758-4137
Luleå University of Technology, Sweden.
RISE - Research Institutes of Sweden, Samhällsbyggnad, Energi och cirkulär ekonomi.ORCID-id: 0000-0002-0359-3652
Vise andre og tillknytning
2018 (engelsk)Inngår i: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 227, s. 742-750Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The process of biogas upgrading with ionic liquids, i.e. pure 1-butyl-3-methylimidazolium bis(trifluoro-methylsulfonyl)imide ([bmim][Tf2N]), aqueous choline chloride/urea (ChCl/Urea), and aqueous 1-allyl-3-methyl imidazole formate ([Amim][HCOO]), was simulated in Aspen Plus and compared with the conventional water scrubbing upgrading technique. The comparisons of the performances on the amount of recirculated solvents and energy usage show the following order: aqueous [Amim][HCOO]<aqueous ChCl/Urea<[bmim][Tf2N]<water. Six different co-digestion plants (anaerobic digestion, AD, plants) were surveyed to acquire data for comparison. The selected plants had different raw biogas production capacities and produced gas with differing methane content. The data confirmed the simulation results that the type of substrate and the configuration of AD process are two factors affecting energy usage, investment cost, as well as operation and maintenance costs for the subsequent biogas upgrading. In addition, the simulation indicated that the energy usage of the ionic liquid-based upgrading was lower than that of the conventional upgrading techniques in Scandinavian AD plants. The estimated cost including investment, operation and maintenance for the ionic liquid technology showed to be lower than that for the water scrubbing upgrading process.

sted, utgiver, år, opplag, sider
2018. Vol. 227, s. 742-750
Emneord [en]
Anaerobic digestion, Biogas upgrading, Ionic liquids, Process simulation, Techno-economic evaluation, Biogas, Computer software, Costs, Economic analysis, Energy utilization, Gas plants, Investments, Liquids, Choline chloride, Estimated costs, Investment costs, Ionic liquid technology, Operation and maintenance, Process simulations
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-31131DOI: 10.1016/j.apenergy.2017.07.067Scopus ID: 2-s2.0-85026290782OAI: oai:DiVA.org:ri-31131DiVA, id: diva2:1136480
Tilgjengelig fra: 2017-08-28 Laget: 2017-08-28 Sist oppdatert: 2019-07-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Björkmalm, JohannaWillquist, Karin

Søk i DiVA

Av forfatter/redaktør
Björkmalm, JohannaWillquist, Karin
Av organisasjonen
I samme tidsskrift
Applied Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 28 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.35.10