Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of optical instruments for fines and filler characterisation
RISE - Research Institutes of Sweden (2017-2019), Bioekonomi. King's College London, UK.ORCID-id: 0000-0002-1467-7413
RISE - Research Institutes of Sweden (2017-2019), Bioekonomi. RISE., Innventia.
KTH Royal Institute of Technology, Sweden.
2017 (engelsk)Inngår i: Nordic Pulp & Paper Research Journal, ISSN 0283-2631, E-ISSN 2000-0669, Vol. 32, nr 1, s. 97-109Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A laser diffractometer and three image-based instruments with spatial resolutions between 0.33 and 10 µm/pixel were compared through measurements on calibration spheres and fine fractions comprising pulp fines of various types, neat PCC filler, and a mixture of fines and fillers. The laser diffractometer was highly sensitive to the keyed in refractive index of the samples, which was calculated based on volume-based mixing rules. A high-resolution flow cytometer and a high-resolution fibre analyser were found to be complimentary for measurements on neat fines and fines/filler mixtures, and superior to the laser diffractometer. When measuring on fillers, the laser diffractometer performed as well as the high-resolution flow cytometer, which was capable of resolving single filler particles. The sizes of the calibration spheres were overestimated by the image-based instruments, and the measurement uncertainty was high. The uncertainty was mainly attributed to the unrestricted particle motion, and the low accuracy to the dissimilar optical properties of the calibration material, compared to fines. Thus, calibration materials with shape and optical properties more similar to fines should be developed.

sted, utgiver, år, opplag, sider
2017. Vol. 32, nr 1, s. 97-109
Emneord [en]
Calibration, Fibre analyser, Fillers, Fines, Flow cytometry, Flow imaging, Imaging particle analysis, Laser diffractometry, Particle size analysis, PCC
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-30291DOI: 10.3183/NPPRJ-2017-32-01-p097-109OAI: oai:DiVA.org:ri-30291DiVA, id: diva2:1130992
Tilgjengelig fra: 2017-08-11 Laget: 2017-08-11 Sist oppdatert: 2020-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Hyll, Kari
Av organisasjonen
I samme tidsskrift
Nordic Pulp & Paper Research Journal

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 88 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.45.0