Comparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid
KTH Royal Institute of Technology, Sweden.
KTH Royal Institute of Technology, Sweden.
RISE., SP – Sveriges Tekniska Forskningsinstitut, SP Sveriges tekniska forskningsinstitut, YKI – Ytkemiska institutet. KTH Royal Institute of Technology, Sweden.
Uppsala Universitet.
2007 (engelsk)Inngår i: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 78, nr 9, s. 093702/1-093702/8Artikkel i tidsskrift (Fagfellevurdert)
Abstract [en]

A number of atomic force microscopy cantilevers have been exhaustively calibrated by a number of techniques to obtain both normal and frictional force constants to evaluate the relative accuracy of the different methods. These were of either direct or indirect character—the latter relies on cantilever resonant frequencies. The so-called Sader [Rev. Sci. Instrum. 70, 3967 (1999)] and Cleveland [Rev. Sci. Instrum. 64, 403 (1993)] techniques are compared for the normal force constant calibration and while agreement was good, a systematic difference was observed. For the torsional force constants, all the techniques displayed a certain scatter but the agreement was highly encouraging. By far the simplest technique is that of Sader, and it is suggested in view of this validation that this method should be generally adopted. The issue of the photodetector calibration is also addressed since this is necessary to obtain the cantilever twist from which the torsional force is calculated. Here a technique of obtaining the torsional photodetector sensitivity by combining the direct and indirect methods is proposed. Direct calibration measurements were conducted in liquid as well as air, and a conversion factor was obtained showing that quantitative friction measurements in liquid are equally feasible provided the correct calibration is performed.

sted, utgiver, år, opplag, sider
2007. Vol. 78, nr 9, s. 093702/1-093702/8
HSV kategori
Identifikatorer
URN: urn:nbn:se:ri:diva-27458OAI: oai:DiVA.org:ri-27458DiVA, id: diva2:1054463
Merknad
A1898Tilgjengelig fra: 2016-12-08 Laget: 2016-12-08 Sist oppdatert: 2020-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen
I samme tidsskrift
Review of Scientific Instruments

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 32 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
v. 2.45.0