Numerical development of EHD cooling systems for laptop applications
University of Leeds, UK ; University of Anbar, Iraq.
University of Leeds, UK.
RISE - Research Institutes of Sweden (2017-2019), ICT, SICS. University of Leeds, UK.ORCID iD: 0000-0001-8266-5038
University of Leeds, UK.
2018 (English)In: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 139, p. 144-156Article in journal (Refereed) Published
Abstract [en]

Electrohydrodynamic (EHD) air blowers are uniquely positioned to overcome the limitations of miniaturized mechanical fans in small-scale and consumer electronic devices. A novel cooling system design using optimized EHD blowers integrated with a plate-fin heat sink is presented and proposed for thin consumer electronics such as laptop applications. A three-dimensional (3D) numerical model is developed and validated to solve the coupled equations of EHD flow and conjugate heat transfer and predict the cooling performance of the integrated EHD system. For a range of heat sink heights from 6 to 12 mm, a parametric study is performed to investigate the influence of geometric parameters and operating conditions on the thermal performance of the EHD systems based on heat sink thermal resistance and the highest operating temperature. Numerical results demonstrate that the proposed EHD cooling system is able to provide effective cooling performance and maintain the temperature within the safe and typical operating range. Under a range of thermal design power (TDP) up to 30 W, trends of predicted operating temperatures show that the developed EHD cooling systems have great potential to compete with mechanical blowers in low-profile laptops with higher TDP, lower device height and reduced installation volume compared to a selected list of current standard laptops available commercially.

Place, publisher, year, edition, pages
2018. Vol. 139, p. 144-156
Keywords [en]
EHD flow cooled heat sink, Electrohydrodynamic (EHD) cooling system, Integrated EHD blowers, Miniaturized electronic applications, Thermal management
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:ri:diva-34294DOI: 10.1016/j.applthermaleng.2018.04.119Scopus ID: 2-s2.0-85046705377OAI: oai:DiVA.org:ri-34294DiVA, id: diva2:1236850
Note

 Funding details: D-11-3102, HCED, Higher Committee for Education Development in Iraq; Funding details: University of Leeds;

Available from: 2018-08-06 Created: 2018-08-06 Last updated: 2023-05-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Summers, Jon

Search in DiVA

By author/editor
Summers, Jon
By organisation
SICS
In the same journal
Applied Thermal Engineering
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 92 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf